A home cooling system has two jobs: move heat out of the house and take water out of the air. Every piece of equipment on this site is some arrangement of the same four parts that do that: a compressor, an outdoor coil, an indoor coil and a fan to move air across each.
The equipment, by where it sits
| Equipment | Where it goes | What it does |
|---|---|---|
| Condenser unit | Outside, on a pad or stand | Holds the compressor and the coil that releases the house's heat outdoors. |
| Air handler | Closet, garage or attic | Holds the blower and the cold coil. Pushes air through the ducts and collects the condensed water. |
| Split system | One of each, joined by copper lines | The standard central air conditioner or heat pump. |
| Central air conditioner | Same places as a split system | Cools only. Heat comes from a furnace or electric strips. |
| Heat pump | Same places as a split system | Cools in summer, reverses to heat in winter. |
| Mini split | Small outdoor unit, indoor unit in the room | Cools and heats one or more rooms without central ducts. |
| Package unit | One cabinet outside or on the roof | All the parts in a single box, ducted into the house. |
| Water heater | Garage, closet or outside wall | Tank, tankless or heat pump. Separate from the air system. |
If you already know you need whole-house cooling and want help choosing a type, go to how to pick between system types.
Capacity: Btu and tons
Capacity is how much heat a system moves in an hour, in British thermal units per hour (Btu/h). One ton of cooling is 12,000 Btu/h. Home systems run from 1.5 to 5 tons in half-ton steps. The size is coded into the model number on the data plate.
| Model number digits | Btu/h | Tons |
|---|---|---|
| 018 | 18,000 | 1.5 |
| 024 | 24,000 | 2 |
| 030 | 30,000 | 2.5 |
| 036 | 36,000 | 3 |
| 042 | 42,000 | 3.5 |
| 048 | 48,000 | 4 |
| 060 | 60,000 | 5 |
The right size comes from a load calculation, known as ACCA Manual J, that adds up heat gain through the walls, roof, windows, air leaks and people. Rules based on square feet alone miss most of what matters: two houses with the same floor area can differ by a ton or more depending on windows, insulation and duct location.
Sensible and latent load
The load has two parts. Sensible load is heat you can read on a thermometer. Latent load is moisture that has to be condensed out of the air. In humid weather the latent share is large, and it is the part an oversized system handles worst. A system that satisfies the thermostat in a few minutes never keeps its coil cold and wet long enough to drain much water. Aim to match the calculated load closely and resist rounding up.
The efficiency ratings
| Rating | What it measures | When it matters most |
|---|---|---|
| SEER2 | Cooling output over a season divided by the electricity used | Long cooling seasons. The main number for comparing systems. |
| EER2 | Cooling efficiency at a steady 95°F outdoors | Peak afternoon heat and peak electric bills. |
| HSPF2 | Heat pump heating output over a season divided by electricity used | Anywhere the heat pump is the main source of heat. |
The "2" marks the test procedure adopted in 2023, which uses higher duct pressure to better reflect real houses. SEER2 numbers come out lower than the old SEER for the same machine, so do not compare a new SEER2 rating directly against an old SEER rating.
Federal minimums for new equipment
| Equipment | Minimum |
|---|---|
| Split air conditioner, Southeast and Southwest, under 45,000 Btu/h | 14.3 SEER2 |
| Split air conditioner, Southeast and Southwest, 45,000 Btu/h and up | 13.8 SEER2 |
| Split air conditioner, North | 13.4 SEER2 |
| Split heat pump, all regions | 14.3 SEER2, 7.5 HSPF2 |
| Package air conditioner or heat pump | 13.4 SEER2, 6.7 HSPF2 |
Above the minimum, each step up saves less than the one before. In a climate where the system runs eight or nine months a year, moving a few points above minimum usually earns its keep. The top of the range is mostly variable-speed equipment, and there the real gain in humid weather is steadier moisture control more than the last bit of efficiency.
Refrigerants in new equipment
New residential air conditioners and heat pumps are built for R-454B or R-32. Both belong to a safety class called A2L, meaning low toxicity and mild flammability, and both have a much lower global warming potential than R-410A, which they replace. R-410A is being phased down and is no longer used in newly manufactured systems. It is still produced in shrinking amounts for servicing equipment that already uses it.
- Refrigerants are not interchangeable. A system uses only the refrigerant named on its plate.
- An R-410A outdoor unit cannot be paired with a new A2L indoor coil, or the other way round. When one half fails on an older system, check whether a matching part still exists before assuming a partial replacement is possible.
- A2L systems add safety measures such as leak sensors on some indoor units and limits on how much charge can serve a small room.
- Buying, handling or adding refrigerant requires EPA Section 608 certification.
Before you compare quotes
- Read the plate on your current outdoor unit and note the size and refrigerant.
- Ask for a Manual J load calculation, not a like-for-like swap.
- Get the AHRI reference number for the proposed outdoor and indoor pairing.
- Compare SEER2 with SEER2, and look at EER2 if your summers are long and hot.
- Ask what is being done about ducts, the condensate drain and the electrical disconnect. These decide how well the new equipment performs.