Total Cool

Home cooling and heating equipment, explained

The parts of a home comfort system, the units they are measured in and the ratings printed on them. Read this page first and the individual guides will go faster.

A home cooling system has two jobs: move heat out of the house and take water out of the air. Every piece of equipment on this site is some arrangement of the same four parts that do that: a compressor, an outdoor coil, an indoor coil and a fan to move air across each.

The equipment, by where it sits

EquipmentWhere it goesWhat it does
Condenser unitOutside, on a pad or standHolds the compressor and the coil that releases the house's heat outdoors.
Air handlerCloset, garage or atticHolds the blower and the cold coil. Pushes air through the ducts and collects the condensed water.
Split systemOne of each, joined by copper linesThe standard central air conditioner or heat pump.
Central air conditionerSame places as a split systemCools only. Heat comes from a furnace or electric strips.
Heat pumpSame places as a split systemCools in summer, reverses to heat in winter.
Mini splitSmall outdoor unit, indoor unit in the roomCools and heats one or more rooms without central ducts.
Package unitOne cabinet outside or on the roofAll the parts in a single box, ducted into the house.
Water heaterGarage, closet or outside wallTank, tankless or heat pump. Separate from the air system.

If you already know you need whole-house cooling and want help choosing a type, go to how to pick between system types.

Capacity: Btu and tons

Capacity is how much heat a system moves in an hour, in British thermal units per hour (Btu/h). One ton of cooling is 12,000 Btu/h. Home systems run from 1.5 to 5 tons in half-ton steps. The size is coded into the model number on the data plate.

Model number digitsBtu/hTons
01818,0001.5
02424,0002
03030,0002.5
03636,0003
04242,0003.5
04848,0004
06060,0005

The right size comes from a load calculation, known as ACCA Manual J, that adds up heat gain through the walls, roof, windows, air leaks and people. Rules based on square feet alone miss most of what matters: two houses with the same floor area can differ by a ton or more depending on windows, insulation and duct location.

Sensible and latent load

The load has two parts. Sensible load is heat you can read on a thermometer. Latent load is moisture that has to be condensed out of the air. In humid weather the latent share is large, and it is the part an oversized system handles worst. A system that satisfies the thermostat in a few minutes never keeps its coil cold and wet long enough to drain much water. Aim to match the calculated load closely and resist rounding up.

The efficiency ratings

RatingWhat it measuresWhen it matters most
SEER2Cooling output over a season divided by the electricity usedLong cooling seasons. The main number for comparing systems.
EER2Cooling efficiency at a steady 95°F outdoorsPeak afternoon heat and peak electric bills.
HSPF2Heat pump heating output over a season divided by electricity usedAnywhere the heat pump is the main source of heat.

The "2" marks the test procedure adopted in 2023, which uses higher duct pressure to better reflect real houses. SEER2 numbers come out lower than the old SEER for the same machine, so do not compare a new SEER2 rating directly against an old SEER rating.

Federal minimums for new equipment

EquipmentMinimum
Split air conditioner, Southeast and Southwest, under 45,000 Btu/h14.3 SEER2
Split air conditioner, Southeast and Southwest, 45,000 Btu/h and up13.8 SEER2
Split air conditioner, North13.4 SEER2
Split heat pump, all regions14.3 SEER2, 7.5 HSPF2
Package air conditioner or heat pump13.4 SEER2, 6.7 HSPF2

Above the minimum, each step up saves less than the one before. In a climate where the system runs eight or nine months a year, moving a few points above minimum usually earns its keep. The top of the range is mostly variable-speed equipment, and there the real gain in humid weather is steadier moisture control more than the last bit of efficiency.

Refrigerants in new equipment

New residential air conditioners and heat pumps are built for R-454B or R-32. Both belong to a safety class called A2L, meaning low toxicity and mild flammability, and both have a much lower global warming potential than R-410A, which they replace. R-410A is being phased down and is no longer used in newly manufactured systems. It is still produced in shrinking amounts for servicing equipment that already uses it.

  • Refrigerants are not interchangeable. A system uses only the refrigerant named on its plate.
  • An R-410A outdoor unit cannot be paired with a new A2L indoor coil, or the other way round. When one half fails on an older system, check whether a matching part still exists before assuming a partial replacement is possible.
  • A2L systems add safety measures such as leak sensors on some indoor units and limits on how much charge can serve a small room.
  • Buying, handling or adding refrigerant requires EPA Section 608 certification.

Before you compare quotes

  1. Read the plate on your current outdoor unit and note the size and refrigerant.
  2. Ask for a Manual J load calculation, not a like-for-like swap.
  3. Get the AHRI reference number for the proposed outdoor and indoor pairing.
  4. Compare SEER2 with SEER2, and look at EER2 if your summers are long and hot.
  5. Ask what is being done about ducts, the condensate drain and the electrical disconnect. These decide how well the new equipment performs.

Not sure whether a question belongs with a contractor, the manufacturer or the permit office? See who to contact for what.