Package units: everything in one cabinet

A package unit holds the compressor, both coils and the blower in a single outdoor cabinet. Two ducts connect it to the house. There is no indoor unit at all.

Choose a package unit when the house has no good place for an indoor air handler: many manufactured homes, homes on crawlspaces, small block houses without a mechanical closet and flat-roofed buildings. Where there is indoor space, a split system offers higher efficiency options and keeps the air-moving parts out of the weather.

How it is laid out

1 2 3 4 5
  1. Outdoor section: compressor, condenser coil and fan.
  2. Indoor section, in the same cabinet: evaporator coil, blower and any heater.
  3. Supply duct carrying cooled air into the house.
  4. Return duct bringing house air back.
  5. Condensate drain. The water is removed outdoors, at the cabinet.

The refrigerant circuit is assembled, charged and sealed at the factory. Nobody brazes lines or weighs in charge on site, which removes a common source of installation error. The installer's work is the ducts, the electrical supply, the drain and the anchoring.

The four types

TypeCoolingHeatingSuits
Package air conditionerElectricOptional electric stripsHot climates where heating is rarely needed.
Package heat pumpElectricHeat pump, with strips as backupAll-electric homes with mild winters. The usual choice in Florida.
Gas/electric ("gas pack")ElectricGas furnace sectionHomes with gas service and real winters.
Dual fuelElectricHeat pump first, gas below a set temperatureCold-winter areas with gas available.

If you are weighing electric heating options, the heat pump guide explains why a heat pump beats strips alone.

Package unit or split system

Package unitSplit system
Indoor space neededNoneCloset, garage or attic for the air handler
Refrigerant work on siteNoneLine set connected, evacuated and charged
Efficiency rangeStarts at 13.4 SEER2. Fewer high-efficiency models.Starts at 14.3 SEER2 in the Southeast. Wide range above.
ExposureEvery part lives outdoors, including the blower and evaporator.Only the condensing unit is outdoors.
DuctsSome duct runs outdoors or through the roofAll ducts inside the building shell or attic
Service accessEverything in one place at ground level, or all on the roofTwo locations
NoiseCompressor and blower are both outsideBlower noise indoors, compressor outside

Supply and return arrangements

  • Horizontal (side) discharge. Both duct openings are on the side of the cabinet. Used for units on a slab beside the house or under a manufactured home's duct crossover.
  • Downflow. Openings are on the bottom. Used on rooftops, where the unit sits on a curb that seals to the roof and the ducts drop straight down.

Many cabinets convert from one to the other with a panel kit. A replacement has to line up with the existing duct openings or curb, so measure those before choosing a model. Adapter curbs exist for mismatched footprints.

What to watch in hot, humid and coastal areas

Outdoor ducts

The short ducts between the cabinet and the wall sit in full sun and rain. They need to be sealed airtight, insulated and wrapped in a weatherproof jacket. A leak here pulls hot, wet outdoor air straight into the return, which raises the load and the indoor humidity at the same time. Look for crushed, sagging or waterlogged duct insulation at every service visit.

Sizing and moisture

The same rules apply as for any system: size to a Manual J load and do not round up. Package units are more often single-stage, so correct sizing matters even more for moisture removal. Two-stage and variable-speed package models exist and are worth a look for humid sites. The equipment overview explains why run time removes moisture.

Corrosion

Because both coils and the blower are in the outdoor cabinet, salt air reaches more of the machine. Near the coast, ask for coated coils and check cabinet panels and the base pan for rust each year. The coil care steps in the condenser unit guide apply here as well.

Anchoring

A package unit is a large, flat-sided box that catches wind. In hurricane-prone areas it has to be fastened to its slab or roof curb to resist the local design wind load, and the curb must be fastened to the structure. In flood zones it is raised on a platform.

Drainage

The drain needs a trap, as on any air handler. Without one the blower can hold water in the pan until it spills into the cabinet or the ducts.

Package unit checklist

  1. Type chosen to suit the fuel and the winters: in a mild climate, usually a package heat pump.
  2. Size from a load calculation, not from the old unit's plate.
  3. Duct openings and footprint checked against the existing curb or wall openings.
  4. Outdoor duct sections sealed, insulated and weatherproofed.
  5. Electrical circuit checked against the new data plate, including any heat strips.
  6. Anchoring and elevation that meet local wind and flood rules.
  7. Trapped drain that discharges away from the slab.