Total Cool

Split system air conditioners

A split system puts the noisy, hot half of an air conditioner outside and the cold half inside, with two copper lines between them. It is the most common central cooling setup in American houses.

A split system is a central air conditioner in two pieces: a condensing unit outdoors and an evaporator coil with a blower indoors, usually inside an air handler. It suits any house with ductwork and a spot for the indoor unit. Size it to a load calculation, and buy the two halves as a matched pair.

How it works

Outdoors Indoors 1 2 3 4 5
  1. The compressor squeezes refrigerant gas until it is hot, and the outdoor coil and fan dump that heat outside. The gas condenses to a liquid.
  2. The small liquid line carries warm liquid refrigerant indoors.
  3. A metering device drops the pressure. The refrigerant turns cold in the evaporator coil and absorbs heat from house air blown across it.
  4. The larger, insulated suction line returns cool gas to the compressor.
  5. Water that condenses on the cold coil runs to a pan and out the drain.

The refrigerant is never used up. It goes around the same loop for the life of the system, and a system that needs refrigerant added has a leak.

Why the two halves must match

The outdoor unit, the indoor coil and the blower are designed and tested as a set. Three things depend on the match:

  • Refrigerant. Both halves must be built for the same one. New outdoor units use R-454B or R-32 and cannot be connected to an older R-410A or R-22 coil.
  • Capacity. A coil too small for the outdoor unit chokes it. A coil that is far too large can raise the coil temperature and reduce moisture removal.
  • Rating. The SEER2 on a quote is valid only for the tested pairing. Ask for the AHRI reference number and compare the model numbers on it with what is installed.

When only one half of an older system fails, it is tempting to replace just that half. If the refrigerant differs, that is not an option. If it matches, it still only makes sense when the surviving half is in good shape and an approved pairing exists.

Sizing for a humid climate

Capacity should come from a Manual J load calculation, with the equipment then chosen against that load. The equipment overview explains tons and Btu. Three points matter most where the air is wet:

  1. Do not round up. An oversized unit cools the air quickly and shuts off before the coil has pulled much water out. Run time is what removes moisture.
  2. Check the latent capacity. Manufacturer performance tables split total capacity into sensible and latent. In humid areas you want a selection that puts a healthy share, often a quarter or more, toward moisture.
  3. Set the airflow on purpose. Around 400 CFM per ton is the standard setting. Setting the blower nearer 350 CFM per ton makes the coil colder and wrings out more water, at a small cost in total capacity.
SignLikely cause
Cool but clammy, runs in short burstsOversized unit, or blower speed set too high
Runs all afternoon and holds the setpointSized about right. Long cycles are normal on design days.
Runs all day and cannot keep upUndersized, low on charge, dirty coil or leaky ducts
Humidity climbs overnightFan set to On, or the unit barely cycles at night

The line set

The two copper lines between the units are called the line set. The suction line is the larger one and is always insulated. The liquid line is the smaller one.

  • The factory charge in the outdoor unit covers a set length of line, commonly 15 feet. Longer runs need refrigerant added by weight according to the installation manual.
  • Line diameters must suit the capacity and the length. Reused lines of the wrong size cost efficiency.
  • Old lines can be reused if they are the right size, clean, leak-free and flushed. When changing refrigerant types, replacing them removes doubt.
  • Suction line insulation that is split or missing sweats heavily in humid air and drips inside walls and attics.

Split air conditioner or split heat pump

The two look identical from the yard. A cooling-only unit is covered in the central air conditioner guide. A heat pump adds a reversing valve so the same equipment can heat. If the house has electric heat, choosing the heat pump version is nearly always the better buy in a mild-winter climate. If you are still deciding between a split system and something else, see how to pick between system types.

Before you replace a split system

  1. Read the data plate on the outdoor unit: capacity digits, refrigerant, minimum circuit ampacity and maximum breaker.
  2. Confirm the new unit's electrical requirements against the existing circuit, breaker and disconnect.
  3. Ask whether the indoor coil, the line set and the thermostat are being replaced, and why or why not.
  4. Have duct leakage and return air sizing looked at. A new system on bad ducts performs like an old one.
  5. Make sure the drain line is cleaned or replaced and has a safety switch.
  6. Get the AHRI reference number and the load calculation with the quote.