Buy a straight-cool air conditioner if you are keeping a gas furnace, or if the house needs almost no heat. If your heat is electric, compare the heat pump version of the same model before deciding, because it cools identically and heats for far less than electric strips. Either way, the choices that decide comfort are the size and the compressor type, not the brand.
Air conditioner or heat pump: the actual difference
The two are the same machine in cooling mode. A heat pump adds a reversing valve and a defrost control so it can also heat. The cooling rating, the sizing and the installation are identical.
| Air conditioner | Heat pump | |
|---|---|---|
| Cooling | Yes | Yes, the same |
| Heating | None. Needs a furnace or electric strips. | Yes. Strips only as backup. |
| Federal minimum, Southeast | 14.3 SEER2 (13.8 at 45,000 Btu/h and up) | 14.3 SEER2 and 7.5 HSPF2 |
| Purchase cost | Lower | Somewhat higher for the same tier |
| Winter running cost with electric heat | High. Strips give one unit of heat per unit of electricity. | Low. Two to four units of heat per unit of electricity. |
| Parts that can fail | Fewer | A few more: reversing valve, defrost board |
The heat pump guide covers the heating side in detail.
When cooling-only is the right call
- The house has a working gas furnace and you want to keep heating with gas. The air conditioner's coil sits on the furnace, and the furnace blower moves the air.
- The house is somewhere it almost never needs heat, and a small strip heater a few nights a year is acceptable.
- You are matching existing equipment in a multi-system house and want the same parts throughout.
What an air conditioner is made of
A central air conditioner is nearly always a split system: a condenser unit outdoors and an evaporator coil indoors, either in an air handler or on top of a furnace. The less common alternative is a package unit with everything in one outdoor cabinet.
The outdoor and indoor parts are sold and rated as a matched pair. The SEER2 on a brochure applies only to a specific combination, listed under an AHRI reference number. A new outdoor unit set on an old indoor coil does not earn the advertised rating, and if the refrigerants differ it cannot be connected at all. New units use R-454B or R-32.
Choosing an efficiency tier
| Tier | Compressor | What you get |
|---|---|---|
| Minimum efficiency | Single-stage | Lowest purchase cost. Comfortable when sized correctly. Simple to repair. |
| Mid efficiency | Single-stage or two-stage | Lower running cost. Two-stage models run long, quiet low-stage cycles that remove more moisture. |
| High efficiency | Variable speed | Lowest running cost, steadiest temperature and humidity, quietest. Highest purchase and repair cost. |
How far up to go depends on how many hours the system runs. In a climate with eight or nine months of cooling, a step or two above the minimum generally pays back within the life of the equipment. Each further step saves less than the one before it. The equipment overview explains SEER2 and EER2 and why the two can rank the same units differently.
Sizing: total capacity is only part of it
An air conditioner's capacity divides into sensible cooling, which lowers the temperature, and latent cooling, which condenses moisture. In humid weather the house needs plenty of both.
- Start with a Manual J load calculation. It gives separate sensible and latent loads for your house.
- Select equipment that covers both without overshooting the total by much. The accepted practice is to stay close to the calculated load, not a half ton or a ton above it.
- Do not copy the old unit's size. Many older systems were oversized, and any insulation, window or duct improvements since then have lowered the load further.
How well it dries the air
An air conditioner removes moisture only while the compressor is running and the coil is cold. Four things control how much it removes:
- Run time. The coil takes several minutes to get cold and wet enough to start draining. Short cycles from an oversized unit never get there.
- Airflow. Slower air across the coil removes more moisture. Around 350 CFM per ton is a common humid-climate setting, against the standard 400.
- Fan setting. Leave the thermostat fan on Auto. On the On setting, the blower evaporates water off the coil back into the house between cycles.
- Staging. Two-stage and variable-speed units run longer at lower output, which keeps the coil wet. Paired with a variable-speed blower and a thermostat that reads humidity, they can slow the air further when the house is damp.
Indoor humidity between about 45% and 55% feels comfortable at a higher thermostat setting. If a correctly sized system still leaves the house above 60%, look for outdoor air leaking in through ducts or the building before blaming the equipment.
Features worth paying for, and not
| Worth it in a humid climate | Less important |
|---|---|
| Two-stage or variable-speed compressor | The last one or two points of SEER2 at the top of the range |
| Variable-speed indoor blower with a dehumidify setting | Proprietary smart thermostats, if a standard one does the job |
| Coated coil if you are near the coast | Brand name, within the same tier |
| A thorough installation: load calculation, sealed ducts, correct charge, working drain | Cabinet styling |
Checklist for choosing an air conditioner
- Decide where heat will come from. If it is electric, compare the heat pump version.
- Get a load calculation and choose the size from it.
- Pick the compressor tier that fits how much the system will run.
- Confirm the indoor coil and outdoor unit are an AHRI-listed match on the same refrigerant.
- Check the electrical requirements on the new data plate against the existing circuit.
- Ask how the blower speed will be set and how the drain is protected.
- Near the coast or in a storm zone, confirm coil protection and anchoring.
Still weighing central air against ductless or a package unit? See how to pick between system types.