Air handlers: the indoor half

The air handler is the indoor cabinet that holds the blower and the cold coil. It moves all the air in the house and removes all the water, which makes it the part that decides how comfortable a humid house feels.

An air handler pairs with a heat pump or air conditioner outdoors. Choose one that is an approved match for the outdoor unit, pick a variable-speed blower if humidity control matters to you, and treat the condensate drain as seriously as the equipment. Most water damage from air conditioning starts at a clogged drain.

What is inside the cabinet

1 2 3 4 5 6
  1. Filter. Return air enters here. A clogged filter starves the whole system.
  2. Blower. Moves air through the cabinet and the ducts.
  3. Evaporator coil. Cold refrigerant inside absorbs heat, and water condenses on the outside.
  4. Electric heat strips, used as backup or main heat.
  5. Float switch. Shuts the system off if water backs up in the pan or drain.
  6. Trap and drain line. Carries the condensate outdoors or to a plumbing drain.

The diagram shows an upflow unit, with air entering the bottom and leaving the top. The same parts are arranged for downflow or horizontal use in attics and crawlspaces, and many cabinets convert between positions. When a gas furnace is used instead, the furnace supplies the blower and a cased coil sits on top of it.

Blower motors and why they matter

Motor typeHow it behavesHumidity control
PSCOne fixed speed per tap. Airflow drops as filters load and ducts resist. Now found mostly in older units.Depends entirely on choosing the right speed tap at installation.
Constant-torque ECMMore efficient, a handful of selectable speeds. Holds airflow somewhat better against resistance.Good when set to the right tap.
Variable-speed ECMAdjusts continuously to hold a target airflow. Ramps up and down gently.Best. Can slow the air on a humidity call so the coil runs colder and wetter.

Airflow settings

The standard target is about 400 cubic feet per minute (CFM) for each ton of cooling. In humid climates installers often set the blower nearer 350 CFM per ton. Slower air stays on the coil longer, the coil runs colder and more moisture condenses. Too slow and the coil can freeze, so the setting stays within the range the manufacturer lists.

The speed is set by a tap, a jumper or dip switches on the control board, or through the thermostat on communicating systems. It is worth asking what it was set to, because the factory default is not always right for the tonnage installed.

Managing the water

On a humid day a home system can pull several gallons of water out of the air. All of it has to leave through a three-quarter inch pipe.

  • Trap. The drain needs a trap so the blower does not pull air up the pipe and hold water in the pan.
  • Slope. The line must fall continuously to its outlet. Sags collect slime and clog.
  • Float switch. A safety switch in the pan or drain line stops the system before water overflows. If your thermostat goes blank or cooling stops on a muggy day, a tripped float switch is a common reason.
  • Secondary pan. An air handler above a ceiling needs an auxiliary pan under it with its own drain or switch.
  • Cleaning. Algae grows quickly in a warm, wet drain. Clear the line at the outdoor end with a wet vacuum once or twice a cooling season, and flush it through the cleanout tee.

Cabinets and ducts in a hot garage or attic also sweat on the outside if insulation is missing or air leaks at seams. Sealed joints and intact insulation stop that.

Heat strips

Electric heat kits slide into the top of the air handler and come in sizes such as 5, 8, 10 and 15 kW. Each kilowatt gives 3,412 Btu/h. With a heat pump they serve as backup, and the heat pump guide explains how to size them. With a straight air conditioner they are the only heat.

The air handler's data plate lists a separate minimum circuit ampacity and maximum breaker for each heat kit size. A 10 kW kit draws about 42 amps at 240 volts before the blower is added, so the heat kit usually decides the size of the indoor unit's circuit. Read the plate the same way as the sample outdoor plate.

Matching and sizing

  • Match the outdoor unit. The coil must use the same refrigerant and be an approved pairing with the condenser unit. The AHRI certificate lists the exact air handler model.
  • Check the metering device. Most current coils use a thermostatic expansion valve (TXV) or electronic valve. Some use a fixed piston that must be the right size for the outdoor unit.
  • Check the ducts. Blowers are rated against a duct resistance, commonly 0.5 inches of water column. Restrictive ducts and filters push many systems well past that, which cuts airflow and adds noise.
  • Choose the filter with the ducts in mind. A thick media filter of 4 inches or so gives fine filtration with less resistance than a 1 inch filter of the same rating.

Air handler checklist

  1. Approved match with the outdoor unit, same refrigerant, confirmed by AHRI number.
  2. Blower speed set for the installed tonnage and the climate.
  3. Drain trapped, sloped and fitted with a float switch. Secondary pan if above a ceiling.
  4. Cabinet seams and duct connections sealed.
  5. Heat kit size chosen on purpose, with the circuit sized from the plate.
  6. Filter slot that takes a standard size you can buy easily, and a door you can reach.

For the outdoor side of the same system, read split systems.