A mini split is the right tool for rooms the central system does not reach, houses with no ducts, and spaces that need their own schedule: a garage conversion, an addition, a workshop, a bedroom that runs hot. Nearly all are heat pumps with variable-speed compressors, so they heat as well as cool and they run quietly for long, slow cycles.
How it is put together
- Indoor unit with its own coil, fan, filter and remote control.
- One hole through the wall, about 3 inches across, sloped slightly down toward the outside.
- The line bundle: two insulated copper refrigerant lines, a control cable and the drain hose.
- Outdoor unit with an inverter compressor.
- Condensate drain, falling all the way to its outlet.
The inverter is what sets mini splits apart from a basic central unit. It lets the compressor slow to a fraction of its full output and hold there, so the system matches the load without the on-and-off cycling of single-stage equipment. That is also why mini split SEER2 ratings run well above typical central systems.
Single-zone or multi-zone
| Single-zone | Multi-zone | |
|---|---|---|
| Layout | One outdoor unit, one indoor unit | One outdoor unit, two to five indoor units |
| Efficiency | Highest ratings | Usually lower than the same brand's single-zone units |
| Lowest output | Can turn down very low | The outdoor unit's minimum is shared, so one small room calling alone may get more than it needs |
| If the outdoor unit fails | One room is affected | Every connected room is affected |
| Outdoor footprint | One unit per room served | One unit for several rooms |
For one or two rooms, separate single-zone systems are often the better-performing choice. Multi-zone earns its place when outdoor space is tight or several rooms are being done at once. All indoor units on one outdoor unit must run in the same mode. They cannot heat one room while cooling another.
Indoor unit styles
- Wall mount. High on a wall. The least expensive and the simplest to install and service.
- Ceiling cassette. Recessed into the ceiling, blowing in one to four directions. Needs space above the ceiling and usually a built-in condensate pump.
- Concealed ducted. Hidden above a ceiling or in a soffit, feeding one to three rooms through short ducts. Only the grilles show.
- Floor console. Low on a wall, for rooms with little wall space up high.
Sizing a mini split
Size each indoor unit to the room it serves. The honest way is a room-by-room load calculation. A west-facing sunroom and a shaded interior bedroom of the same floor area can need very different capacities.
| Nominal size | Tons | Typical use |
|---|---|---|
| 9,000 Btu/h | 0.75 | Bedroom, office |
| 12,000 Btu/h | 1 | Large bedroom, single garage bay, studio |
| 18,000 Btu/h | 1.5 | Living room, two-car garage, open addition |
| 24,000 Btu/h | 2 | Large open living area |
Garages, sunrooms and rooms with lots of glass or little insulation need more than their floor area suggests. Insulate and seal the space first if you can. It lets you buy a smaller unit that runs more steadily.
Do not oversize for humidity
An inverter forgives some oversizing, since it can slow down. It cannot slow below its minimum output. A unit far too large for a small room reaches the setpoint, shuts off and leaves the moisture behind, the same problem as an oversized central system. When choosing between two sizes for a humid room, look at the minimum capacity in the specifications as well as the maximum.
Most units have a dry mode that runs the coil cold and the fan slow to favor moisture removal. It helps on mild, damp days when there is little heat to remove. It does not replace correct sizing.
What installation involves
- Mount the indoor unit's bracket level on the wall and bore the hole.
- Set the outdoor unit on a pad, stand or wall bracket, with the clearances the manual calls for.
- Run the line set, cable and drain between the two.
- Connect the refrigerant lines. On a conventional system this means making flare connections, tightening them to a specified torque, pressure testing with nitrogen, pulling a deep vacuum with a pump and micron gauge, then releasing the factory charge.
- Provide a dedicated electrical circuit and an outdoor disconnect, sized from the unit's data plate.
Step 4 is where most failed installs go wrong, and working with refrigerant requires EPA Section 608 certification. Some systems are sold for owner installation with line sets that arrive pre-charged and sealed, joined with quick-connect fittings so no vacuum pump is needed. Zone Air, for example, sells AHRI Certified R-454B systems of this kind, with pre-charged line sets cut to the length each room needs, from 5 to 75 feet. The electrical work, permits and anchoring rules are the same whichever kind of system you install.
Notes for hot, humid and coastal sites
- Clean the filters often. Every few weeks in a long cooling season. Indoor coils and blower wheels stay damp and grow mildew if dust builds up, so plan on a deeper cleaning now and then.
- Mind the drain. The hose must fall the whole way. If it cannot, use a condensate pump. A sagging drain is the usual cause of water running down the wall.
- Insulate both refrigerant lines and seal the wall hole, or the lines will sweat inside the wall.
- Protect the outdoor unit. Salt air and storm winds affect a mini split's outdoor unit exactly as they do a central one. Anchor it and rinse the coil as described in the condenser unit guide.
- Closed doors defeat a single indoor unit. One wall unit in a hallway will not cool bedrooms behind shut doors. Give each closed room its own unit, or use a concealed ducted unit to serve two or three.
Comparing ductless with a ducted system for the whole house? See how to pick between system types and the split system guide.